Analog conductivity measuring cells tetraCon 325 WTW Germany
Price Not Announced
In Stock
Semua sel pengukur konduktivitas analog dilengkapi dengan kompensasi suhu terintegrasi dan mencakup semua aplikasi
Di instalasi pengolahan air limbah, sebagai pengukuran aliran atau di dalam pipa: Solusi yang tepat untuk setiap aplikasi
Linearitas tertinggi oleh 4 sel pengukur elektroda
Keamanan operasional tinggi dengan desain yang kuat
You have the application – we have the measuring cell! With the conductivity measuring cells by WTW, measurements of 0.0001 µS/cm to 2 S/cm are not a problem. The unique 4 electrode measuring cell compensates for possible contamination and polarization effects. All measuring cells can be connected to the LF monitor LF 298 NTC (exception: TetraCon® 700).
TetraCon 700 – Designed as an immersion encoder specifically for use in wastewater treatment plants
Conductivity measuring cell with 4 electrode system, integrated temperature sensor, anti-slip electrodes and breakage-resistance shaft; measuring range 10 µS/cm to 1000 mS/cm.
Only as replacement armature for analog monitors of the Ecoline® or QuadroLine® series. Still available as digital version (IQ Sensor Net System 181).
TetraCon 325 – for universal applications
4 electrode measuring cell with graphite electrodes and integrated temperature sensor, measuring range 1 µS/cm to 2000 mS/cm.
LRD 01 – for the installation into pipelines
Conductivity measuring cell as V4A model. With integrated temperature sensor (up to 130 °C), measuring range 0.001 to 200 µS/cm, pressure-resistant to 14 bar, 1/2 inch NPT screw thread.
LRD 325 – for the installation into pipelines
Conductivity measuring cell with integrated temperature sensor (up to 100 °C). Measuring range 1 µS/cm to 2 S/cm, pressure-resistant to 10 bar, 1/2 inch NPT screw thread.
LR 325/01 – for pure water measurement
Pure water measuring cell with integrated temperature sensor and flow vessel, measuring range 0.001 to 200 µS/cm. Especially suited for the measurement of low conductivity values such as in boiler infeed water.
LR 325/001 – for trace measurement, also in partial and non-waterous media
High resolution trace conductivity measuring cell with integrated temperature sensor and flow vessel, measuring range 0.0001 to 30 µS/cm.
Technical Data
Analog conductivity measuring cells | |||
---|---|---|---|
Model | TetraCon® 700 (SW) | LRD 01 | LRD 325 |
Measuring principle | 4 electrode measuring cell | 2 electrode measuring cell | 4 electrode measuring cell |
Measuring range | 10 µS/cm … 1000 mS/cm | 0,001 µS/cm… 200 µS/cm | 0.001 µS/cm… 200 µS/cm |
Cell constant | K=0.917 cm-1 (in free solution) K=0.933 cm-1 (with flow fitting EBST 700-DU/N) | K=0.1 cm-1 | K=0.475 cm-1 |
Temperature sensor | Integrated NTC | ||
Temperature measurement | 0 … +50 °C | 0 … +130 °C | 0 … +100 °C |
Max. pressure | 10 bar (at 20 °C) | 14 bar (at 20 °C) | 10 bar (at 20 °C) |
Conductivity measuring cells for special applications | |||
---|---|---|---|
Model | TetraCon® 325 | LR 325/01 | LR 325/001 |
Measuring principle | 4-electrode measuring cell | 2-electrode measuring cell | 2-electrode measuring cell |
Measuring range | 1 µS/cm … 2 S/cm | 0.011 µS/cm … 200 µS/cm | 0.0001 µS/cm … 30 µS/cm |
Cell constant | K=0.475 cm-1 | K=0.1 cm-1 | K=0,01 cm-1 |
Temperature sensor | integrated |