+62 (031) 8284914, 085100605225, 085100974976, Fax. +62 (031) 8284955 sumberarumabadi@gmail.com
4700

STAT FAX 4700 MICROWELL READER NEOGEN USA

Product Description

4700

Neogen 4700 Microwell Reader Item 9303

2.5 Specifications
Photometric
Linear Measurement Range: …………………0.00 to 3.0 Absorbance Units (A)
Photometric Accuracy:………………………….+/- (1% +/- 0.010) 0.0 through 1.5 ABS
………………………………………………………….+/- (2% +/- 0.010) 1.5 through 3.0 ABS
Stability:……………………………………………..Drift of no more than 0.005A in 8 hours
bichromatic
Light Source: ………………………………………Tungsten-Xenon lamp with lamp saver
feature
Standard Wavelengths:  Standard:405, 450, 492, and 650nm
Filter Type:………………………………………….IAD hardcoat interference, 10nm half
bandpass
Vessel:……………………………………………….Single, or break a part strips up to 12
wells long, 3 strip loading capacity
Electronic
Display:………………………………………………Interactive touch screen 3.5” (8cm) LCD,
color graphic display
Printer: ……………………………………………….Thermal dot matrix with graphic capability
Power Requirements:…………………………..100-240 VAC, 1.2 A (universal input)
Microprocessor:…………………………………..50MHz eZ80, 64K EEPROM
Memory:……………………………………………..2MB Flash Memory, 1MB static RAM
Memory
Interface:…………………………………………….USB mouse; USB port used for thumb
drive interface for firmware updates
(mouse not included; thumb drive not
included); USB port B for connection to
PC (cable not included)
Software
Speed: ……………………………………………….Reads, calculates and prints results, 30
seconds per 12-well strip
Calculation Modes: ………………………………Single point calibration by standard or
factor, multipoint calibration with point-topoint curve fit, linear regressions with log,
lin, and log-logit selections, cubic spline
and cut off mode selections
8  NEOGEN ReaderOperator’s Manual Doc. 4701 Rev. B
Specifications (Continued)
Test Menu:………………………………………….Total of 120 open channelsto store tests.
Stores all parameters including
wavelengths, calculations, unit codes,
ranges, interpretations, calibrator values,
test names, and previous curve
Other
Enclosure:…………………………………………..Painted flame-retardant ABS plastic cover
and base
Dimensions:………………………………………..Approximately 9”x13.5”x5” (24x34x13cm)
weight: 5 lbs (2.3kg)
Certifications:………………………………………Pending
Environmental Conditions for Safe Operation
Indoor use   Altitude up to 2000m   Temperature 5°C to 40°C (Although it may  be safe to operate in these conditions, it
may not be suitable for the performance of
your tests; check with your supplier.)
Humidity 80% for temperatures up to 31°C, decreasing linearity to 50% humidity
at 40°C Mains supply voltage fluctuations
not to exceed +10% of nominal voltage
Recommended Environmental Conditions
Recommended Operating Temperature ….18-35°C
Recommended Operating Humidity:……….less than 80%
Storage Temperature:    10 to 50°C
Design and instrument specifications are subject to change without notice